LCR-VM Linglong Series Online Soft Starter Panel - High-Performance Control Solution from China Suppliers and Factory
Product Overview
New appearance design, English LCD screen display, VM logo highlights its personality.
Choose online soft starter for the control cabinet, small and powerful, convenient after-sales.
64-bit singlechip + core algorithm, large driving torque, deal with overloaded equipment easily.
Control power supply AC100-500V voltage design, more stable and reliable, adapt to more fields.
With the motor full time super protection function, such as input/output missing, over/underload, over/undervoltage, instantaneous overcurrent, three-phase imbalance blocking, phase sequence detection, start timeout, frequent start and thyristor overheating.
Built-in standard 485 communication, 0-20 mA or 4-20 mA.
Built-in standard 1-way programmable relay output, can achieve custom output of many functions (see internal parameters for details).
Built-in 1 piece D1 programmable terminal, can achieve more functional applications, such as fault reset (NO), instantaneous stop protection/external fault (NC) water shortage protection (NO), power-on startup ( two wires start-stop control ) and jog control.
Can customize shell cloud function, support mobile and computer terminal parameter setting and start-stop control.
Specification of LCR-VM Linglong Series Online Soft Starter Panel
| No. | Specification | Physical Dimension/mm | Package weight/kg |
|---|---|---|---|
| 1 | 5.5-18.5kW | 450*300*200 (iron box) | 6.7 |
| 2 | 5.5-18.5kW | 450*300*200 (stainless steel box) | 5.5 |
| 3 | 22-75kW | 750*280*280 | 13.6 |
| 4 | 90-115kW | 850*350*330 | 21.6 |
| 5 | 132-220kW | 1100*450*380 | 39 |
| 6 | 250-320kW | 1250*520*400 | 49.5 |
Frequently Asked Questions (FAQ)
Q What is the voltage range supported by the LCR-VM series soft starter control power supply?
The control power supply of the LCR-VM series soft starter panel features a wide voltage design of AC100-500V. This wide range ensures more stable, reliable operation and makes it highly adaptable to various industrial fields and grid environments.
Q What kind of motor protection functions are built into this soft starter?
It provides full-time comprehensive motor protection, including input/output phase loss, over/underload, over/undervoltage, instantaneous overcurrent, three-phase imbalance blocking, phase sequence detection, start timeout, frequent start, and thyristor overheating protection.
Q Does the LCR-VM series soft starter support remote control and cloud connectivity?
Yes, the LCR-VM series supports customizable shell cloud functions. This allows users to set parameters and manage start-stop controls remotely via both mobile devices and computer terminals.
Q How do I configure the D1 programmable terminal on this soft starter panel?
The built-in D1 programmable terminal can be used to set up various functional applications such as fault reset (Normally Open), instantaneous stop protection/external fault (Normally Closed), water shortage protection (Normally Open), power-on startup (two-wire start-stop control), and jog control.
Q What are the physical dimensions and weight options for the 5.5-18.5kW models?
The 5.5-18.5kW models come in two enclosure types with the same physical dimension of 450*300*200 mm. The iron box version weighs 6.7 kg, while the stainless steel box version weighs 5.5 kg.
Q What communication protocols does the LCR-VM series support?
The unit comes with built-in standard RS485 communication interfaces, and supports standard analog signal outputs of either 0-20 mA or 4-20 mA for seamless integration into industrial automation networks.